Images may not accurately represent the product. Please refer to the product Name and Description when placing your order.
Ships by CPAC Equipment, Inc. within 7 to 14 business days
Available Options
* ADDITIONAL SHIPPING RATES
The Industry’s Most Efficient High-Capacity Tabletop Sterilizer
A proven advancement in RapidCycle™ sterilization, the RH-Pro11 sterilizer will raise your level of sterilization efficiency. Using Cutting-Edge HVHA (High-Velocity Hot Air)
technology, the RH-Pro11 provides the fastest instrument turnaround of any FDA-Cleared sterilization technology. No steam or water means no lengthy drying cycle with
longer instrument life free of corrosion.
For Healthcare, the RH-Pro11 can Eliminate “Immediate-Use” Steam Sterilization, shortened cycles, work-arounds, and Joint Commission scrutiny. With four (4) removable trays, the RH-Pro11 chamber can be easily modified to handle all sizes of instrument sets.
Features:
With four (4) removable trays, the RH-Pro11 chamber can be easily modified to handle all sizes of instrument sets.
The RH-PRO11 Advantage
• FDA-Cleared 6 Minute Sterilization Cycles (Unwrapped)
• FDA-Cleared 12 Minute Sterilization Cycles (Wrapped)
• Large Table-Top Capacity (2295 Cubic Inches)
• Uses 65% Less Energy Than Steam
• Non-Corrosive Sterilizer Environment
• Full 3-Year Warranty
• Waterless Sterilization with No Chemicals
• Greater Capacity — Four Large Trays
Specifications:
Sterilization Cycle Times
Total Sterilization Processing Times 375°F
Unwrapped Instruments – 14 Minutes
Handpieces 16 Minutes
Wrapped / Pouched Instruments – 21 Minutes
Wrapped Cassettes 40 Minutes
Total Sterilization Processing Time Low-Temperature
320°F – 42 Minutes
300°F – 58 Minutes
280°F – 126 Minutes
The RapidHeat RH-Pro Advantage
No Dry Cycle
Improves Instrument Turnaround Time and removes the threat of environmental contamination and instrument corrosion from wet instruments.
No Water
Saves Time & Improves Patient Safety – With no water required, the potential for contamination from improperly cleaned water reservoirs is eliminated.
No Extensive Maintenance
There is no costly and time-consuming maintenance – Only a few minutes a week is needed to ensure the safe and effective operation of an RH-Pro Sterilizer.
Low-Temperature Cycle Options
CPAC has created low-temperature cycles to process devices/instruments that are known or could potentially become degraded by RapidHeat’s standard High-Temperature cycle of 375°F.
Three temperature cycles: 320°F (160°C), 300°F (149°C), 280°F (138°C)
Choice of three low-temperature cycles
Allows user to validate and verify 12-log kill sterilization
Eliminates heat-sensitive device concerns
Time/temperature profiles equivalent to steam
Unlike traditional Dry Heat, RapidHeat™ is an advanced thermal sterilization technology circulating high velocity hot air in a sealed chamber at 200 to 300 air exchanges per minute.
RH-Pro11 Installation and Operation Video
Cassette Wrapping and Taping Instructions
Do you like this product? Tell other people. Leave a review!
Rating :
AAO endorses Orthazone's ecommerce supplies platform. Orthazone pays royalty fees to the AAO. These fees are used for the general purposes of the AAO. The AAO does not certify, guarantee, or warrant the products, services, or offerings provided Orthazone, its platform or its employees, agents, subcontractors, or vendor. The AAO will not be liable for any indirect, special, incidental, or consequential loss or damage of any kind, including lost profits (whether or not the parties have been advised of such loss or damage) arising in any way in connection with the products and services offered by Orthazone.
Transform Your Practice With Zone Practice Solutions