Register Login
Serving The Orthodontic Community Since 2015
1 7 3 2 9
Customers
0
SHOPPING CART
YOUR SHOPPING CART IS EMPTY!
Categories
Menu
0
SHOPPING CART
YOUR SHOPPING CART IS EMPTY!
800-833-7132
Inventory
management
Invoice
management
Dashboard
Payment
Slider
Lab case
Tracker
CATEGORIES

Refurbished SciCan Statim G4 5000 Cassette Autoclave

Product Code:

104-DLS

Product ID :

31643

Supplier: Duraline
Brand: Duraline

Ships within 3 TO 6 Day(s)

Views :

13,457

Regular Price:
$5,668.99
You could save $396.83 on this order
VIP price: $5,272.16
Learn how to save

Available Options


* Additional Shipping Rates

* Select Base Product

Add to Cart

Refurbished SciCan Statim G4 5000 Cassette Autoclave

Scican Statim 5000 G4 Cassette Sterilizer, Refurbished

WARRANTY: 6 months parts and labor

FAST.
STATIM's unmatched speed and dependability have made STATIM the world's best-selling autoclave. And its patented gentle technology has made STATIM the world's favourite.

FORWARD.
The STATIM G4 will offer you a level of interactivity never seen before. The STATIM G4, through its LCD touch screen control and STATIM Live networking capability, has been designed to provide you with unprecedented ease of use and puts the user in total control.

SciCan’s innovative G4 Technology, now WiFi enabled, automatically records and monitors every cycle 24/7 so the tedious task of manually logging cycle data can now be done automatically and error-free. Logging accurate cycle information has never been so effortless, simple and efficient. STATIM G4 Technology detects human or mechanical error before it costs time and money.

Benefits of the G4 network:

  • Monitoring real-time cycle data
  • Instant data logging
  • Proactive maintenance management
  • Automatic system updates to your G4 machines

Features:

  • Immediate Steam Generation - Unlike conventional autoclaves that need to heat an entire reservoir of water, STATIM uses only a small, specific amount of water required for each cycle. Water is introduced into a heating device referred to as a ‘steam generator’, rapidly heated and converted to steam in mere seconds.
  • Air Removal - Using PPPD technology and our patented steam injection process – air is automatically forced out of the sterilization chamber Cassette System - The thin stainless steel walls of STATIM’s fully-removable cassette, (or sterilization chamber) allow for rapid heating and cooling of the chamber. As a result, STATIM meets the conditions for sterilization and drying in a fraction of the time required by a conventional autoclave
  • Drying Technology - The STATIM 2000 and 5000 have each been designed to provide you with a complete solution: rapid sterilization balanced by rapid drying
  • Touch - A large 3.5” high-resolution touchscreen offers a vivid display of messages, current cycle information and customizable colours all with extraordinary clarity. Fully adjustable contrast levels let you optimize the screen to the lighting in your steri-centre
  • Connect - Through your networked portal, you can view not only your STATIMs current operations in real time, you can also access cycle history, printing and validation information, and also sterilization records. Capable of sending emails with cycle information errors directly to your dealer, your STATIM G4 will let qualified technicians know when service is imminent
  • Protect - Patient safety relies on attention to detail. The STATIM G4 supports verifiable processes that are PIN protected with user-defined IDs so that staff members can be required to authorize a cycle. This encourages extra attention to process and creates a safer environment for both staff and patients
  • Collect - An undocumented sterilization cycle might as well not have been performed. With each cycle, information must be stored to protect your office and your patient. The integrated DataLogger stores all cycle information for the lifetime of the unit, which is accessible through multiple channels such as: a USB port for manual retrieval; an Ethernet connection for web based archiving or desktop printing; or a RS232 port for an external printer option.
  • Immediate Steam Generation - Unlike conventional autoclaves that need to heat an entire reservoir of water, STATIM uses only a small, specific amount of water required for each cycle. Water is introduced into a heating device referred to as a ‘steam generator’, rapidly heated and converted to steam in mere seconds.
  • Air Removal - Using PPPD technology and our patented steam injection process – air is automatically forced out of the sterilization chamber Cassette System - The thin stainless steel walls of STATIM’s fully-removable cassette, (or sterilization chamber) allow for rapid heating and cooling of the chamber. As a result, STATIM meets the conditions for sterilization and drying in a fraction of the time required by a conventional autoclave
  • Drying Technology - The STATIM 2000 and 5000 have each been designed to provide you with a complete solution: rapid sterilization balanced by rapid drying
  • Touch - A large 3.5” high-resolution touchscreen offers a vivid display of messages, current cycle information and customizable colours all with extraordinary clarity. Fully adjustable contrast levels let you optimize the screen to the lighting in your steri-centre
  • Connect - Through your networked portal, you can view not only your STATIMs current operations in real time, you can also access cycle history, printing and validation information, and also sterilization records. Capable of sending emails with cycle information errors directly to your dealer, your STATIM G4 will let qualified technicians know when service is imminent
  • Protect - Patient safety relies on attention to detail. The STATIM G4 supports verifiable processes that are PIN protected with user-defined IDs so that staff members can be required to authorize a cycle. This encourages extra attention to process and creates a safer environment for both staff and patients
  • Collect - An undocumented sterilization cycle might as well not have been performed. With each cycle, information must be stored to protect your office and your patient. The integrated DataLogger stores all cycle information for the lifetime of the unit, which is accessible through multiple channels such as: a USB port for manual retrieval; an Ethernet connection for web based archiving or desktop printing; or a RS232 port for an external printer option.

Technical Specs:

  • Controls: Automatic
  • Dimensions (L x W x H): 23.6” x 16.1” x 7.5”
  • Cassette internal dimensions: 15” x 7” x 3”
  • Cassettes: 1
  • Voltage: 115V, 50/60 Hz, 15A / 1450 W
  • Weight without water: 73 lbs (33 kg)
Reviews (0)
write a review

Do you like this product? Tell other people. Leave a review!

Write a review
Note: HTML is not translated!

Rating :

There are no reviews for this product.
0